亚洲ⅴ欧洲第一的日产av,久久99青青精品免费观看,四虎国产精品成人免费久久,婷婷人人爽人人爽人人片,国产精品毛片完整版视频,国产小视频在线高清播放,人妻精品久久无码专区精东影业,99久久国内精品成人免费,怡春院欧美一区二区三区免费,成人福利国产精品视频

您好,歡迎來(lái)到濟(jì)南通宇恒成自動(dòng)化工程有限公司網(wǎng)站!

服務(wù)熱線

常見(jiàn)問(wèn)題
新聞中心

仿威圖機(jī)箱電氣柜成套怎樣才能更美觀?

發(fā)布時(shí)間:2023-06-10 來(lái)源:http://m.kisansushi.com/ 瀏覽量:

1.折彎
1. Bending
所有的電線在敷設(shè)時(shí),都講究橫平豎直,配電箱也一樣。但是在配電箱接線中,雖然要求“直”,同時(shí)還要求不允許出現(xiàn)90°角。
All wires should be laid horizontally and vertically, and the same applies to distribution boxes. However, in the wiring of the distribution box, although it is required to be "straight", it is also required that no 90 ° angle is allowed.
這樣做是因?yàn)椋?dāng)電線的彎折角度大于90°后,就會(huì)對(duì)電線的絕緣層造成傷害——明顯的就是絕緣層發(fā)白、變色。后果就是降低絕緣層的耐性,對(duì)絕緣性、 阻燃性都有較大影響。
This is because when the bending angle of the wire is greater than 90 °, it will cause damage to the insulation layer of the wire - the most obvious is the whitening and discoloration of the insulation layer. The consequence is to reduce the durability of the insulation layer, which has a significant impact on both insulation and flame retardancy.
標(biāo)準(zhǔn)的做法是,所有需要折彎的地方,都折成圓弧形的角,同時(shí)還要保證縱向電線與橫向電線垂直。
The standard practice is to fold all areas that need to be bent into circular corners, while also ensuring that the longitudinal wires are perpendicular to the transverse wires.
2.交叉
2. Intersection
有兩種情況會(huì)出現(xiàn)交叉,種是沒(méi)有按照上文所說(shuō)的,做到區(qū)分縱向的電線和橫向電線,更不用說(shuō)保證兩者垂直了。當(dāng)電線亂七八糟的排列在配電箱里,勢(shì)必會(huì)造成電線較差。這樣做的后果是配電箱內(nèi)雜亂,一旦出現(xiàn)故障,維修起來(lái)會(huì)很麻煩。
There are two situations where there may be intersections. The first is that the distinction between longitudinal and transverse wires has not been made as mentioned earlier, let alone ensuring that the two are perpendicular. When the wires are arranged in a disorderly manner in the distribution box, it is bound to cause poor wiring. The consequence of doing so is that the distribution box is messy, and once a malfunction occurs, it can be very troublesome to repair.
另一種情況就比較嚴(yán)重了,是指橫平豎直的進(jìn)線與出線存在交叉。
Another situation is more serious, which refers to the intersection of horizontal and vertical incoming and outgoing lines.
在圖中,主開(kāi)關(guān)的出線從開(kāi)關(guān)的左側(cè)繞過(guò),接到右側(cè)斷路器的上口。這樣一來(lái),勢(shì)必會(huì)造成主開(kāi)關(guān)的出線和主開(kāi)關(guān)的進(jìn)線交叉。這樣做有兩個(gè)后果:①主開(kāi)關(guān)的進(jìn)線會(huì)受到出線的壓迫,導(dǎo)致進(jìn)線接線不牢固;②在斷開(kāi)主開(kāi)關(guān)對(duì)配電箱進(jìn)行維修時(shí),維修人員就有可能在維修主開(kāi)關(guān)出線時(shí)接觸到帶電的進(jìn)線,導(dǎo)致觸電。
In the figure, the outgoing line of the main switch bypasses the left side of the switch and connects to the upper port of the right circuit breaker. In this way, it will inevitably cause the outgoing line of the main switch to cross with the incoming line of the main switch. There are two consequences of doing this: ① the incoming line of the main switch will be compressed by the outgoing line, resulting in unstable incoming wiring; ② When disconnecting the main switch for maintenance of the distribution box, maintenance personnel may come into contact with live incoming lines during the maintenance of the main switch outgoing line, resulting in electric shock.
電氣成套
3.跳線
3. Jumper
這個(gè)配電箱存在出線與進(jìn)線交叉的情況,這屬于上一節(jié)的內(nèi)容,不再多說(shuō)。我們單看主開(kāi)關(guān)的出線——主開(kāi)關(guān)后面有四個(gè)分開(kāi)關(guān),卻只從主開(kāi)關(guān)的出線接線柱引出了2根線(零火線各一根)。那它是怎么為后面四個(gè)分開(kāi)關(guān)提供電源的呢?(零線直接接到了零排上,我們不再管它。)
This distribution box has a situation where the outgoing and incoming lines intersect, which belongs to the previous section and will not be further discussed. Let's just look at the outgoing lines of the main switch - there are four sub switches behind the main switch, but only two wires (one neutral wire and one live wire) are led out from the outgoing terminal of the main switch. How does it provide power for the following four sub switches? (The zero line is directly connected to the zero line, and we will no longer care about it.)
方法是將出線接到個(gè)分開(kāi)關(guān),再?gòu)膫€(gè)分開(kāi)關(guān)的進(jìn)線接線柱引出一條線,接到第二個(gè)分開(kāi)關(guān)……這樣一來(lái),、二、三個(gè)分開(kāi)管的上口接線柱,便都接了兩根線。這種從前一個(gè)斷路器上口取電源的方法,就叫做“跳線”。跳線的接法,早在2010年就被國(guó)標(biāo)禁止,原因如下。
The method is to connect the outgoing line to the first sub switch, and then lead a line from the incoming terminal of the first sub switch to the second sub switch... In this way, the upper terminal of the first, second, and three separate pipes are all connected with two lines. This method of taking power from the previous circuit breaker is called "jumper". The connection of jumpers was prohibited by the national standard as early as 2010, for the following reasons.
跳線的危害
Hazards of Jumpers
箱內(nèi)線,一般為4平方毫米或2.5平方毫米,4平方毫米的電線,大載流量為25A以上(數(shù)據(jù)來(lái)源于《GB/T 4706.1-2005》)。一個(gè)五孔插座的額定電流是10A,一個(gè)三孔插座的額定電流是16A,整個(gè)房間會(huì)有多少個(gè)插座?因此,25A的載流量很明顯不夠,是會(huì)引起電線過(guò)載的。
The internal wire of the box is generally 4 square millimeters or 2.5 square millimeters, with a maximum current carrying capacity of 25A or more for wires of 4 square millimeters (data sourced from GB/T 4706.1-2005). The rated current of a five hole socket is 10A, and the rated current of a three hole socket is 16A. How many sockets will there be in the entire room? Therefore, the current carrying capacity of 25A is clearly insufficient and can cause wire overload.
入戶線一般為6平方毫米,大載流量為32A以上,能夠滿足家用(因此要求家庭總開(kāi)關(guān)的額定電流不超過(guò)32A)。
The entrance line is generally 6 square millimeters, with a maximum current carrying capacity of 32A or above, which can meet the requirements of household use (therefore, the rated current of the home main switch should not exceed 32A).
那么,如果我把箱內(nèi)電線換掉,也換成6平方毫米的行不行?答案是不行!電線太粗,勢(shì)必會(huì)擠壓箱內(nèi)空間,影響散熱。家用PZ30箱要求,電線不得超過(guò)4平方毫米。
So, if I replace the wires inside the box, can I also replace them with 6 square millimeters? The answer is no! If the wires are too thick, they will inevitably squeeze the space inside the box and affect heat dissipation. Household PZ30 boxes require that the wires should not exceed 4 square millimeters.
正確的接法為,每有一個(gè)支路斷路器,就要從主開(kāi)關(guān)下口引出一條線。
The correct connection method is to lead a line from the lower port of the main switch for each branch circuit breaker.
本文由電氣成套友情奉獻(xiàn).更多有關(guān)的知識(shí)請(qǐng)點(diǎn)擊: http://m.kisansushi.com 真誠(chéng)的態(tài)度.為您提供為的服務(wù).更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn).敬請(qǐng)期待.
This article is dedicated to the friendship of electrical equipment. For more relevant knowledge, please click on: http://m.kisansushi.com Sincere attitude. We will provide you with comprehensive services. We will gradually contribute more relevant knowledge to everyone. Stay tuned
首頁(yè)首頁(yè) 產(chǎn)品產(chǎn)品 電話電話 置頂置頂
国产91特黄特色A级毛片| 日韩中文精品亚洲第三区| 国产精品视频免费网站| 国产精品蜜芽在线观看| 无码啪啪精品天堂浪潮av| 99久久久无码国产精品| 午夜国产小视频| 免费A级毛片无码A∨蜜芽试看| 午夜理论片yy8860y影院| 亚洲综合第一页| 小13箩利洗澡无码视频免费网站| 一本本月无码-| 久久精品国产亚洲精品色婷婷| 成人av一区二区三区| 国产精品一线天在线播放| 国产一级一极性活片免费观看| 免费 国产 无码久久久| 清纯唯美经典一区二区| 亚洲国产精品久久久天堂麻豆宅男| 欧美成人精品三级网站视频| 精品亚洲女同一区二区| 成人黄网站免费永久在线观看| 91久久大香伊蕉在人线| 亚洲中文字幕在线无码一区二区| 在线观看国产一区亚洲bd| 亚洲一线二线三线品牌精华液久久久| 国产精品无遮挡又爽又黄| 野花免费观看高清电视| 一区二区三区av天堂| 极品少妇被后入内射视| 无码AV午夜福利一区| 亚洲三级视频在线观看| 国产精品丝袜在线不卡| 国产精品一区中文字幕| 免费人成在线观看网站| 久久精品国产福利国产秒拍| 亚洲一级无毛片无码在线免费视频| 久久精品人妻中文系列| 99久久国产综合精品成人影院| 加勒比色老久久综合网| 97超碰精品成人国产|